Temperature Test Chambers
Series T
The CTS “T” series is distinguished by technical advantages as well as attractive design. The temperature test chambers in this series have high temperature change rates, simple programming on a colour touchscreen panel, as well as extremely low noise levels. They are designed as modular units allowing a custom solution for nearly every requirement profile
.
- Minimum external measurements due to compact method of construction
- Optimised parameters for highest testing precision
- Minimum noise level
Test space capacity in litres:
100 / 200 / 350 / 600 / 1000 / 1500
Temperature range:
+10 °C / +180 °C
-20 °C / +180 °C
-40 °C / +180 °C
-70 °C / +180 °C

Standard version of the product line “T”:
- multicolour touch panel / 32 Bit Controller
- single-hand operated door handle, lockable
- entry port ø 50 mm
- shelf, stainless steel
- error display in plain text
- potential free contact for malfunction signal
- Ethernet interface
CTS user benefits:
Test space capacity in litres:
100 / 200 / 350 / 600 / 1000 / 1500
Temperature range:
+10 °C / +180 °C
-20 °C / +180 °C
-40 °C / +180 °C
-70 °C / +180 °C
Design:
Control: microprocessor control and monitoring system
Test space: stainless steel grade 1.4301
Refrigerants: chloride free, hermetically sealed
Options:
- Additional entry ports ø 50 mm, 80 mm und 125 mm
- Additional shelves
- Panoramic window, multiple glazed, sized 570 x 710 mm; for units ≥ 200 ltr.
- Glove box hand-hole in the door
- Additional Pt 100 for temperature measuring on test specimen alternative reversible to controller function
- Air dryer system
- Mobile unit design – wheels
- Temperature protection for test-specimen
- Water cooled compressor – transfer heat out of the test area
- CID software for programming and documentation
- Variable air speed in the test space
- RS 232 interface
- USB Port
Other chamber sizes and options on request.
Type |
T -40/100
|
T -40/200
|
T -40/350
|
T -40/600
|
T -40/1000
|
T -40/1500
|
||
Test Space |
liters |
100 |
200 |
350 |
600 |
1000 |
1500 |
|
Test Space Dimensions | height |
mm, appr. |
500 |
750 |
750 |
850 |
900 |
900 |
width |
mm, appr. |
500 |
650 |
650 |
850 |
1000 |
1000 |
|
depth |
mm, appr. |
400 |
400 |
720 |
830 |
1100 |
1600 |
|
Overall Dimensions | height |
mm, appr. |
1630 |
1800 |
1800 |
1900 |
1950 |
1950 |
width |
mm, appr. |
770 |
920 |
920 |
1120 |
1270 |
1270 |
|
depth |
mm, appr. |
860 |
1345 |
1665 |
1875 |
2245 |
2745 |
|
Temperature Tests |
||||||||
Temperature Range | T -40/… |
°C |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
-40/+180 |
T -70/… |
°C |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
-70/+180 |
|
Temp. Change Rate Cooling acc. IEC 60068-3-5 |
T -40/… |
K/min |
6,0 |
4,0 |
4,0 |
3,5 |
3,0 |
2,5 |
T -70/… |
K/min |
8,0 |
4,0 |
3,5 |
3,0 |
2,5 |
2,0 |
|
Temp. Change Rate Heating acc. IEC 60068-3-5 |
T -40/… |
K/min |
6,0 |
4,0 |
3,5 |
3,5 |
3,0 |
3,5 |
T -70/… |
K/min |
6,0 |
4,0 |
3,5 |
3,5 |
2,5 |
3,5 |
|
max. Thermal Load at +20°C |
T -40/… |
W |
1400 |
3500 |
3500 |
4000 |
4000 |
4000 |
T -70/… |
W |
1200 |
3000 |
3000 |
4000 |
4000 |
4000 |
|
Temperature Fluctuation |
K |
≤± 0,3 |
||||||
Nominal Voltage |
230 V |
400 V +6% -10%, 3/N, 50 Hz |
||||||
Nominal Power | T -40/… |
kW, appr. |
3,5 |
6,0 |
6,0 |
7,2 |
7,4 |
9,4 |
T -70/… |
kW, appr. |
6,5 |
7,2 |
7,2 |
8,7 |
8,9 |
10,8 |
|
Condenser |
air-cooled |
|||||||
Weight | T -40/… |
kg, appr. |
280 |
400 |
500 |
550 |
800 |
950 |
T -70/… |
kg, appr. |
300 |
450 |
550 |
600 |
850 |
1050 |
|
Noise level |
dB(A) |
< 60 |
< 58 |
< 58 |
< 58 |
< 58 |
< 58 |
All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options.
We reserve the right to make alterations due to technical development.