CLIMATIC TEST CHAMBERS
Series C
In addition to the advantages of our CTS Temperature Test Chambers, CTS climatic test cabinets also offer you the option of including humidity as a stress factor in your simulation tests.
Humidity is measured by a capacitive humidity sensor giving high accuracy, long-term stability and low maintenance requirements. CTS places great value on the quality detailed throughout all its system components. CTS rigorously use only the best supplier components such as compressors and solenoid valves. This results in significant advantages for you in long-term, malfunction-free operation, ensuring that you do not lose valuable testing time.
- Minimum external measurements due to compact method of construction
- Optimised parameters for highest testing precision
- Minimum noise level
Test space capacity in litres:
100 / 200 / 350 / 600 / 1000 / 1500
Temperature range:
+10 °C / +180 °C
-20 °C / +180 °C
-40 °C / +180 °C
-70 °C / +180 °C
Humidity range:
10 – 95 % RH

Standard version of the product line “C”:
- Multicolour touch panel / 32 Bit Controller
- The service-friendly capacitive humidity measurement system
- Single-hand operated door handle, lockable
- Entry port ø 50 mm
- Shelf, stainless steel
- Error display in plain text
- Potential free contact for malfunction signal
- Ethernet Interface
CTS user benefits:
- service-friendly construction
- minimum noise level
- high temperature change rate
- simple user-friendly operation and programming
- low power-consumption
- optimised parameters for highest testing precision
- complies with current CE and EMC regulation
Test space capacity in litres:
100 / 200 / 350 / 600 / 1000 / 1500
Temperature range:
+10 °C / +180 °C
-20 °C / +180 °C
-40 °C / +180 °C
-70 °C / +180 °C
Humidity range:
10 – 95 % RH
Design:
Control: microprocessor control and monitoring system
Test space: stainless steel grade 1.4301
Refrigerants: chloride free, hermetically sealed
Humidity system: Capacitive measuring
Options:
- Additional entry ports ø 50 mm, 80 mm and 125 mm
- Additional shelves
- Panoramic window, multiple glazed, sized 570 x 710 mm; for units ≥ 200 ltr.
- Glove box hand-hole in the door
- Additional Pt 100 for temperature measuring on test specimen alternative reversible to controller function
- Air dryer system
- Mobile unit design – wheels
- Temperature protection for test-specimen
- Water cooled compressor – transfer heat out of the test area
- CID software for programming and documentation
- Variable air speed in the test space
- RS 232 interface
- USB Port
Type | C -40/100 | C -40/200 | C -40/350 | C -40/600 | C -40/1000 | C -40/1500 | ||
Test Space | liters | 100 | 200 | 350 | 600 | 1000 | 1500 | |
Test Space Dimensions | height | mm, appr. | 500 | 750 | 750 | 850 | 900 | 900 |
width | mm, appr. | 500 | 650 | 650 | 850 | 1000 | 1000 | |
depth | mm, appr. | 400 | 400 | 720 | 830 | 1100 | 1600 | |
Overall Dimensions | height | mm, appr. | 1630 | 1800 | 1800 | 1900 | 1950 | 1950 |
width | mm, appr. | 770 | 920 | 920 | 1120 | 1270 | 1270 | |
depth | mm, appr. | 860 | 1345 | 1665 | 1875 | 2245 | 2745 | |
Temperature Tests | ||||||||
Temperature Range | C -40/… | °C | -40/+180 | -40/+180 | -40/+180 | -40/+180 | -40/+180 | -40/+180 |
C -70/… | °C | -70/+180 | -70/+180 | -70/+180 | -70/+180 | -70/+180 | -70/+180 | |
Temp. Change Rate Cooling acc. IEC 60068-3-5 | C -40/… | K/min | 5,0 | 4,0 | 4,0 | 3,5 | 3,0 | 2,5 |
C -70/… | K/min | 2,0 | 4,0 | 3,5 | 3,0 | 2,5 | 2,0 | |
Temp. Change Rate Heating acc. IEC 60068-3-5 | C -40/… | K/min | 3,0 | 4,0 | 3,5 | 3,5 | 3,0 | 3,5 |
C -70/… | K/min | 3,0 | 4,0 | 3,5 | 3,5 | 2,5 | 3,5 | |
max. Thermal Load at +20°C | C -40/… | W | 1400 | 3500 | 3500 | 4000 | 4000 | 4000 |
C -70/… | W | 700 | 3000 | 3000 | 4000 | 4000 | 4000 | |
Temperature Fluctuation | K | ≤± 0,3 | ||||||
Climatic Tests | ||||||||
Temperature Range | °C | +10 to +95 | ||||||
Humidity Range | % RH | 10 to 98 | ||||||
Dew Point Range 1 | °C | +7 to +94 | ||||||
Dew Point Range 2 | °C | -7 to +7 | -10 to +7 | |||||
Humidity Fluctuation 1 | % RH | ≤± 1,5 | ||||||
Humidity Fluctuation 2 | % RH | ≤± 3 | ||||||
Temperature Fluctuation | K | ≤± 0,3 | ||||||
Nominal Voltage | 230 V | 400 V +6% -10%, 3/N, 50 Hz | ||||||
Nominal Power | C -40/… | kW, appr. | 4,1 | 7,1 | 7,1 | 8,2 | 8,5 | 9,2 |
C -70/… | kW, appr. | 4,1 | 7,1 | 7,, | 8,7 | 8,9 | 10,8 | |
Condenser | air-cooled | |||||||
Weight | C -40/… | kg, appr. | 350 | 450 | 500 | 550 | 800 | 950 |
C -70/… | kg, appr. | 380 | 500 | 550 | 600 | 850 | 1050 | |
Noise level | dB(A) | 55 | < 58 | < 58 | < 58 | < 58 | < 58 |
All figures are average values which have been obtained at a temperature of +25° C, without test specimens, without thermal load and without options.
Click to download CTS Temperature Test Chambers PDF